Chapter 8 Servo Parameters
Please note:
1. This parameter can be set any time. However, it is effective only when the electronic
2. ASDA-A2 series L type models does not provide Electronic Cam (E-Cam) function.
P5 - 20
ACO
Default: 200
Applicable Control Mode: PR
Unit: msec
Range: 1 ~ 65500
Data Size: 16-bit
Display Format: Decimal
Settings:
In PR mode, this parameter is used to set the acceleration and deceleration time, i.e.
the necessary time when the motor reachs the speed of 3000 r/min from 0.
P5 - 21
AC1
Default: 300
Applicable Control Mode: PR
Unit: msec
Range: 1 ~ 65500
Data Size: 16-bit
Display Format: Decimal
Settings:
Refer to P5-20 for explanation.
P5 - 22
AC2
Default: 500
Applicable Control Mode: PR
Unit: msec
Range: 1 ~ 65500
Data Size: 16-bit
Display Format: Decimal
Settings:
Refer to P5-20 for explanation.
8-132
Call 1(800)985-6929 for Sales
gear is engaged.
Accel / Decel Time 0
Accel / Decel Time 1
Accel / Decel Time 2
deltaacdrives.com
deltaacdrives.com
sales@deltaacdrives.com
Address: 0528H, 0529H
Related Section:
Section 7.10
Address: 052AH, 052BH
Related Section:
Section 7.10
Address: 052CH, 052DH
Related Section:
Section 7.10