6) P4-11 ~ P4-21
Communication read-out parameters for ASDA-A2 series are including:
Group 0: P0-00 ~ P0-46
Group 1: P1-00 ~ P1-76
Group 2: P2-00 ~ P2-67
Group 3: P3-00 ~ P3-11
Group 4: P4-00 ~ P4-23
Group 5: P5-00 ~ P5-99
Group 6: P6-00 ~ P6-99
Group 7: P7-00 ~ P7-27
9-18
Call 1(800)985-6929 for Sales
deltaacdrives.com
These parameters are for offset adjustment. Do not change the factory
default setting if not necessary. If the user desires to change the settings of
these parameters, the user has to set the value of the parameter P2-08 to 22
(hexadecimal: 16H) first and then restart. After restarting, the settings of
parameters P4-11 to P4-21 can become modified.