Chapter 6 Control Modes of Operation
P1 - 05
MON2
Default: 100
Applicable Control Mode: ALL
Unit: % (full scale)
Range: 0 ~ 100
Data Size: 16-bit
Display Format: Decimal
P4 - 20
DOF1
Default: Factory setting
Applicable Control Mode: ALL
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Display Format: Decimal
Settings:
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4 - 21
DOF2
Default: Factory setting
Applicable Control Mode: ALL
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Display Format: Decimal
Settings:
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
For example, when the users want to observe the analog voltage signal of channel 1, if
the monitor output setting range is 8V per 325Kpps, then it is needed to change the
setting value of parameter P1-04 (Analog Monitor Output Proportion 1) to 50
(=325Kpps/Max. input frequency). Other related parameters setting include parameter P0-
03 (A=3) and P1-03 (A=0~3, output polarity setting). In general, when output voltage
value of Ch1 is V1, the pulse command frequency is equal to (Max. input frequency ×
V1/8) × P1-04/100.
6-56
Call 1(800)985-6929 for Sales
deltaacdrives.com
Analog Monitor Output Proportion 2 (CH2)
Analog Monitor Output Drift Adjustment
(CH1)
Analog Monitor Output Drift Adjustment
(CH2)
deltaacdrives.com
sales@deltaacdrives.com
Address: 010AH, 010BH
Related Section:
Section 6.4.4
Address: 0428H, 0429H
Related Section:
Section 6.4.4
Address: 042AH, 042BH
Related Section:
Section 6.4.4