Delta Electronics ASDA-A2 Series User Manual page 330

High resolution ac servo drive for network communication applications
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
P2 - 22
DO5
Default: 7
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 013Fh
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
Refer to P2-18 for explanation.
P2 - 23
NCF1
Default: 1000
Applicable Control Mode: ALL
Unit: Hz
Range: 50 ~ 1000
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set first resonance frequency of mechanical system. It can be
used to suppress the resonance of mechanical system and reduce the vibration of
mechanical system.
If P2-24 is set to 0, this parameter is disabled.
The parameters P2-23 and P2-24 are the first group of notch filter parameters and the
parameters P2-43 and P2-44 are the second group of notch filter parameters.
P2 - 24
DPH1
Default: 0
Applicable Control Mode: ALL
Unit: dB
Range: 0 ~ 32
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set magnitude of the resonance suppression that is set by
parameter P2-23. If P2-24 is set to 0, the parameters P2-23 and P2-24 are both disabled.
The parameters P2-23 and P2-24 are the first group of notch filter parameters and the
parameters P2-43 and P2-44 are the second group of notch filter parameters.
Revision January 2011
Call 1(800)985-6929 for Sales
deltaacdrives.com
Digital Output Terminal 5 (DO5)
Notch Filter 1 (Resonance Suppression)
Notch Filter Attenuation Rate 1
(Resonance Suppression)
deltaacdrives.com
sales@deltaacdrives.com
Chapter 8 Servo Parameters
Address: 022CH, 022DH
Related Section: Table 8.B
Address: 022EH, 022FH
Related Section:
Section 6.3.7
Address: 0230H, 0231H
Related Section:
Section 6.3.7
sales@deltaacdrives.com