Chapter 8 Servo Parameters
P5 - 08
SWLP
Default: 2147483647
Applicable Control Mode: PR
Unit: PUU
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Display Format: Decimal
P5 - 09
SWLN
Default: -2147483648
Applicable Control Mode: PR
Unit: PUU
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Display Format: Decimal
P5 - 10★
AYSZ
Default: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: read only
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set the data amount of data arrady (N x 32 bits). N is the
capacity of the data array.
P5 - 11 
AYID
Default: 0
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ (P5-10-1)
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set the data address when reading and writing data array.
8-128
Call 1(800)985-6929 for Sales
deltaacdrives.com
Forward Software Limit
Reverse Software Limit
Data Array: Data Amount (N x 32 bits)
Data Array: Read / Write Address
deltaacdrives.com
sales@deltaacdrives.com
Address: 0510H, 0511H
Related Section: N/A
Address: 0512H, 0513H
Related Section: N/A
Address: 0514H, 0515H
Related Section: Section 7.2
Address: 0516H, 0517H
Related Section: Section 7.2