Relevant parameters:
P1 - 06
SFLT
Default: 0
Applicable Control Mode: S
Unit: msec
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display Format: Decimal
6.3.4 Analog Speed Input Scaling
The analog voltage between V_REF and GND determines the motor speed command.
Using with parameter P1-40 (Max. Analog Speed Command) can adjust the speed control
ramp and its range.
Revision January 2011
Call 1(800)985-6929 for Sales
deltaacdrives.com
Accel / Decel Smooth Constant of Analog
Speed Command (Low-pass Filter)
Target Speed
5000rpm
3000rpm
-10
-5
5
-3000rpm
-5000rpm
deltaacdrives.com
Chapter 6 Control Modes of Operation
Related Section:
Section 6.3.3
SFLT
The speed control ramp is
determined by parameter P1-40
Analog Input Voltage (V)