Chapter 8 Servo Parameters
P2 - 25
NLP
Default: 2 (1kW and below models) or
Applicable Control Mode: ALL
Unit: 0.1 msec
Range: 0 ~ 1000
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set low-pass filter time constant of resonance suppression.
If P2-25 is set to 0, this parameter is disabled.
P2 - 26
DST
Default: 0
Applicable Control Mode: ALL
Unit: 0.001
Range: 0 ~ 1023
Data Size: 16-bit
Display Format: Decimal
Settings:
If P2-26 is set to 0, this parameter is disabled.
P2 - 27
GCC
Default: 0
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 4
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
Gain Switching Condition Settings:
8-86
Call 1(800)985-6929 for Sales
deltaacdrives.com
Low-pass Filter Time Constant
(Resonance Suppression)
5 (other models)
External Anti-Interference Gain
Gain Switching Control Selection
deltaacdrives.com
sales@deltaacdrives.com
Address: 0232H, 0233H
Related Section:
Section 6.3.7
Address: 0234H, 0235H
Related Section: N/A
Address: 0236H, 0237H
Related Section: N/A
Revision January 2011