Chapter 8 Servo Parameters
P5 - 38 
CANO
Default: 1
Applicable Control Mode: ALL
Unit: N/A
Range: 1 ~ (P5-10 – P5-36)
Data Size: 16-bit
Display Format: Decimal
Settings:
When the compare function is not enabled, using this parameter can set the estimated
capture amount (able to read and write).
Once the capture function is enabled, everytime when one position is captured, the
setting value of P5-38 will decrease 1. When the setting value of P5-38 is equal to 0, it
indicates that the capture operation has finished.
Please note:
1. The total amount of COMPARE, CAPTURE and E-Cam data can not exceed the
2. ASDA-A2 series L type models does not provide Electronic Cam (E-Cam) function.
P5 - 39 
CACT
Default: 0x2010
Applicable Control Mode: ALL
Unit: N/A
Range: 0x0000 ~ 0xF13F
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
This parameter is used to determine the capture source and enable the capture
function.
A: Capture function settings:
8-138
Call 1(800)985-6929 for Sales
CAPTURE: Capture Amount
number of 800.
CAPTURE: Capture Source Setting
A
B
C
D
Low Word
deltaacdrives.com
deltaacdrives.com
sales@deltaacdrives.com
Address: 054CH, 054DH
Related Section:
Section 7.11.1
Address: 054EH, 054FH
Related Section:
Section 7.11.1
Revision January 2011
sales@deltaacdrives.com