P1 - 39
SSPD
Default: 3000
Applicable Control Mode: ALL
Unit: r/min
Range: 0 ~ 5000
Data Size: 16-bit
Display Format: Decimal
Settings:
When target motor speed reaches its preset value, digital output (TSPD) is enabled.
When the forward and reverse speed of servo motor is equal and higher than the
setting value, the motor will reach the target motor speed, and then TSPD signal will
output.
TSPD is activated once the drive has detected the motor has reached the Target Motor
Speed setting as defined in parameter P1-39. TSPD will remain activated until the motor
speed drops below the Target Motor Speed.
P1 - 40 ▲
VCM
Default: rated speed
Applicable Control Mode: S, T
Unit: r/min
Range: 0 ~ 10000
Data Size: 16-bit
Display Format: Decimal
Settings:
In Speed mode, this parameter is used to set the maximum analog speed command
based on the maximum input voltage (10V).
In Torque mode, this parameter is used to set the maximum analog speed limit based
on the maximum input voltage (10V).
For example, in speed mode, if P1-40 is set to 3000 and the input voltage is 10V, it
indicates that the speed command is 3000 r/min. If P1-40 is set to 3000, but the input
voltage is changed to 5V, then the speed command is changed to 1500 r/min.
Speed Command / Limit = Input Voltage Value x Setting value of P1-40 / 10
Revision January 2011
Call 1(800)985-6929 for Sales
deltaacdrives.com
Target Motor Speed
Max. Analog Speed Command or Limit
deltaacdrives.com
sales@deltaacdrives.com
Chapter 8 Servo Parameters
Address: 014EH, 014FH
Related Section: Table 8.A
Address: 0150H, 0151H
Related Section:
Section 6.3.4
sales@deltaacdrives.com
8-63

Advertisement

Table of Contents
loading

Table of Contents