Replacing The Uv Lamps - Stratasys Objet350 User Manual

3d printing system
Hide thumbs Also See for Objet350:
Table of Contents

Advertisement

Objet350 User Guide
Replacing the UV Lamps
The UV lamps used for curing models have a long, but limited, working life. You 
can test and adjust their effective power with the UV Calibration wizard (see 
"Testing and Calibrating the UV Lamps" on page 6-65). If you need to replace a 
UV lamp bulb or UV reflector, follow these instructions: 
To replace the UV lamp bulb or UV reflector:
1.  Make sure the printer is in offline mode.
Warning
Before continuing, make sure that the safety interlock is not defeated, and that 
the UV lamp is not hot.
2.  Start the UV Lamp Replacement wizard from the Options menu. 
3.  Make sure that the build tray is empty, and confirm this in the wizard screen. 
DOC-17001 Rev. L
Figure 6-110    Offline mode indicator (red)
The online/offline button at the bottom of the printer interface should be red. If 
not, click it to switch the printer to offline mode.
Then, close the printer, and click Next.
Figure 6-111    Tray confirmation
The axes move to the "home" position.
6 Operating and Maintaining the Printer
6-76

Advertisement

Table of Contents
loading

Table of Contents