Pin Assignments And Signal Descriptions; Safety; Assignment Of Standard I/O Connection For Robot Control - Fronius Robacta TX W Operating Instructions Manual

Torch body changeover system
Table of Contents

Advertisement

Pin assignments and signal descriptions

Safety

Assignment of
standard I/O con-
nection for robot
control
Pin
1
2
3
4
5
6
7
8
9
10
30
WARNING! Operating the equipment incorrectly can cause serious injury and
damage. All the functions described may only be used by trained and qualified
personnel. Do not use the functions described until you have thoroughly read and
understood the following documents:
-
these operating instructions
-
all the operating instructions for the system components, especially the safe-
ty instructions
WARNING! Machines that start up automatically can cause serious injury and
damage. The device may only be powered through an Emergency Stop circuit.
CAUTION! Risk of damage to connection supply due to overcurrent. Secure sup-
ply against overcurrent with a 1.5 A slow-blow fuse.
NOTE! To avoid faults, keep the cable between the torch body changeover sta-
tion and the robot control as short as possible.
4
3
2
1
9
8
7
6
15
14
13
12
11
22 21 20 19 18 17 16
28 27 26 25 24 23
33 32 31 30 29
37 36 35 34
Input (from the
Output (from the
torch body
robot to the
changeover sta-
torch body
tion to the ro-
changeover sta-
bot)
tion)
X
X
X
X
X
X
X
X
X
X
5
10
Signal
+ 24 V
GND
Torch body sensor 1
Torch body sensor 2
Torch body sensor 3
Torch body sensor 4
Torch body sensor 5
Torch body sensor 6
Torch body sensor 7
Torch body sensor 8