Pressing The Emergency Release Button - Fronius Robacta TX W Operating Instructions Manual

Torch body changeover system
Table of Contents

Advertisement

Pressing the
emergency re-
lease button
(3)
(1)
(2)
(4)
Remove the plastic placeholder (1)
1
from the plastic sleeve on the torch
body coupling (2)
Unscrew the grub screw (3) from the
2
torch body coupling using a 1.5 mm Al-
len key
NOTE! The opening in the plastic
sleeve of the torch body coupling
must be directly above the ex-
posed hole in the torch body cou-
pling.
Press the compressed air pistol (4)
3
firmly into the plastic sleeve on the
torch body coupling
Actuate the compressed air pistol and
4
at the same time pull the torch body off
the torch body coupling
Send the torch body coupling and cen-
5
tre bolt to the manufacturer