Changing The Welding Torch Flange - Fronius Robacta TX W Operating Instructions Manual

Torch body changeover system
Table of Contents

Advertisement

Changing the
welding torch
flange
118
(1)
(1)
(3)
(7)
(5)
Undo the screws (1)
1
Remove the torch body insulation (2)
2
(1)
(1)
(2)
Undo all six grub screws (3) on the wel-
3
ding torch flange (4)
(4)
Remove old welding torch flange (4)
4
(3)
Fit assembly aid (5) onto torch body
5
Push new welding torch flange (4) as
6
far as it will go onto the torch body
Tighten all six grub screws (3) on the
7
welding torch flange (4)
-
Remove the assembly aid (5)
8
(6)
(4)
NOTE! The pin (6) with a diameter
of 4 mm (0.16 in.) must fit into the
hole (7) on the welding torch
flange
NOTE! Always tighten the oppo-
site grub screw. Do not tighten
grub screws one-by-one in a circu-
lar fashion
Tightening torque = 1.5 Nm