Installing The Torch Body Changeover Station - In Conjunction With Vr 1500 / Vr 1530 / Vr 1550; Safety; General; Preparation - Fronius Robacta TX W Operating Instructions Manual

Torch body changeover system
Table of Contents

Advertisement

Installing the torch body changeover station - in con-
junction with VR 1500 / VR 1530 / VR 1550

Safety

General

Preparation

CAUTION! Risk of injury from compressed air escaping unintentionally. The torch
body changeover station must remain depressurised and de-energised until in-
stallation has been completed.
NOTE! For wire-feed units with the "Welding torch gas purging" option, limit the
gas purging pressure to max. 6.00 bar (87.02 psi).
(1)
(2)
(3)
(3)
Secure junction valve (1) on the moun-
1
ting plate (2) as shown using the
screws, washers and nuts provided
Undo screws (3)
2
Disconnect compressed air line from
3
welding torch gas purging connection
(4)
(4)