Fitting The New Torch Body Sensor - Fronius Robacta TX W Operating Instructions Manual

Torch body changeover system
Table of Contents

Advertisement

Fitting the new
torch body sen-
sor
(4)
(3)
(5)
(7)
(6)
(1)
(2)
Undo cable tie (3)
3
Unplug the plug from the PC board ac-
4
cording to the position of the rack hol-
der. In this case (4)
Example:
-
Torch body rack mounted at posi-
tion 2 on the rack holder - unplug
the torch body sensor at connecti-
on 'X3 sensor 2' on the PC board
in the torch body changeover sta-
tion
Remove the cable tie (5)
5
Undo screw (6)
6
-
using a 4 mm Allen key
Feed out the sensor cable from the
7
torch body changeover station
Unscrew the torch body sensor (7)
8
from the torch body rack
Screw the new torch body sensor into
1
the torch body rack until it reaches the
dimension shown
Tighten screw (1)
2
-
using a 4 mm Allen key
Fix the sensor cable to the torch body
3
rack using the cable tie (2)