Changing The Torch Body Manually; Safety - Fronius Robacta TX W Operating Instructions Manual

Torch body changeover system
Table of Contents

Advertisement

Changing the torch body manually

Safety

Changing the
1
torch body manu-
ally
68
CAUTION! Risk of injury from escaping compressed air and flying parts from the
torch body coupling. When manually changing the torch body, always wear the
following protective equipment:
-
ear protection
-
protective goggles with side protection
-
gloves - electrically insulated and providing protection against heat
When carrying out the following work, position the robot arm and the torch body cou-
pling so that
-
the Unlock/Lock button on the torch body changeover station can be pressed with
one hand
-
the torch body can be placed onto or removed from the torch body coupling with
the other hand
Hold the torch body on the robot arm
2
with one hand
Press and hold the Unlock/Lock button
3
(1) on the torch body changeover stati-
on
-
Torch body coupling lock (2)
opens
(1)
Remove torch body from torch body
4
coupling
Place torch body back onto the torch
5
body coupling, press against the torch
body coupling and hold in this position
Release the Unlock/Lock button on the
6
torch body changeover station
-
lock closes
-
Torch body is fixed after approx. 5
seconds
(2)