Removing 2.5-Inch Hdd/Ssd Modules - Fujitsu PRIMERGY RX4770 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

7.4.3

Removing 2.5-inch HDD/SSD modules

Customer Replaceable
Unit (CRU)
Tools:
tool-less
Preliminary steps
▶ If the HDD/SSD module to be removed is combined into a RAID array,
please proceed as follows:
RAID level
RAID 0
RAID 1
RAID 5
In order to permanently remove an operational HDD/SSD module that is part of
a RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
RX4770 M6
Hard disk drive (HDD) / solid state disk (SSD)
Procedure
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all
data are lost!
Removing an HDD/SSD module from a RAID 1 or
RAID 5 array will not result in data loss. However,
the removed drive needs to be replaced
immediately by an HDD/SSD module of the same
or larger capacity.
After replacing the HDD/SSD module,
RAID rebuild will be performed as a
background process, see
RAID array rebuild" on page
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Performing a
105.