If the server has been powered off (power plugs must be disconnected) it is
possible to indicate the faulty component by pressing the indicate CSS button.
The LEDs have the following meaning:
Indicator
F - Controller
G - CPU
H - Memory
K - System fan off
P - LC pump
16.2.2
Server front
16.2.2.1
Connectors on the server front
Figure 247: Connectors on the front panel
1
Front VGA connector
RX4770 M6
Status
Description
off
Controller okay
Controller failure (PCI card installed on riser
orange on
card)
off
CPU okay
orange on
CPU failure
off
memory module running
orange on
memory module failure
system fan running
orange on
system fan failure
off
LC pump okay
orange on
LC pump faulty
Upgrade and Maintenance Manual
2
USB 3.0 connector (x2)
Appendix A
403