Replacing An M.2 Ssd - Fujitsu PRIMERGY RX4770 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

15.6.4

Replacing an M.2 SSD

Upgrade and Repair Unit
(URU)
Tools:
Phillips PH2 / (+) No. 2 screw driver (for cover 2)
If maintenance work involving parts replacement and expansion is
performed in an environment where Windows Server is installed,
reauthentication of Windows Server may be necessary. If re-
authentication is required, inform the customers or system engineer.
Preliminary steps
"Locating the defective server" on page
▶ If applicable,
"Removing the front cover with lock" on page
"Shutting down the server" on page
"Disconnecting the power cord" on page
"Getting access to the component" on page
▶ Remove the riser modules, see
"Removing the fan cage" on page
"Removing the air duct 1 (top system board)" on page
"Removing the top system board carrier" on page
"Removing the OCP air duct" on page
Replacing the M.2 SSD
▶ Remove the defective M.2 SSD, see
▶ Install the new M.2 SSD, see
RX4770 M6
46.
"Removing a riser module" on page
64.
70.
"Removing the M.2 SSD" on page
"Installing the M.2 SSD" on page
Upgrade and Maintenance Manual
System board and components
Hardware: 30 minutes
Software: 15 minutes
97.
47.
48.
68.
73.
45.
63.
357.
353.
359