Basic software procedures
pairs. In this case, the memory mode will automatically revert to Independent
Channel Mode.
For more information on memory modes available for your server, see
"Basic information" on page
After replacing the defective module(s) the memory mode is automatically
reset to its original state. It is recommended to verify that the memory mode
has been correctly.
▶ Enter the BIOS.
▶ Select the Configuration menu.
▶ Select Memory Status and verify that none of the memory modules are
marked as Failed.
▶ Select Memory Configuration to verify Memory Mode.
▶ Save your changes (if applicable) and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.3.10

Verifying the system time settings

This task only applies to Linux and VMware environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
If a Linux/VMware OS is used and the hardware clock has been configured as
UTC (Universal Time, Coordinated) in the OS, the BMC local time may not be
mapped correctly.
▶ After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
▶ Enter the BIOS.
100
236.
Upgrade and Maintenance Manual
RX4770 M6

Advertisement

Table of Contents
loading