Performing A Fan Test - Fujitsu PRIMERGY RX4770 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Basic software procedures
Using the ID icon in the iRMC S5 web interface
▶ Log in to the iRMC S5 web interface.
The icon that represents the ID indicator LED resides on the right of the
menu bar. Its color symbolizes its status:
blue: the ID LED is on.
grey: the ID LED is off.
▶ Click the icon to switch the ID indicator LED on or off.
Using ServerView Operations Manager
▶ In ServerView Operations Manager Single System View and press the
Locate button in the title bar to switch off the ID indicator.
5.3.19

Performing a fan test

Notes on replacing a defective fan
After replacing a defective system fan or PSU containing a defective fan,
the fan error indicators will stay lit until the next fan test. By default, a fan
test is automatically started every 24 hours. The first automatic fan test
being performed after replacing a fan will turn off the fan error indicator.
If you want to start the fan test manually, you can do so by following the
description below:
Executing the fan test via the iRMC S5 web interface
▶ Log into the iRMC S5 web interface.
The System menu is displayed on default.
▶ Open the Cooling page.
▶ Expand the Cooling Devices group.
▶ Click Start Fan Test.
For more information on iRMC settings, see the iRMC user guides.