Omron E5 D Series Communications Manual page 99

Digital temperature controllers
Hide thumbs Also See for E5 D Series:

Advertisement

Address
Parameter name
Four-byt
Two-byt
e mode
e mode
0D24
2D12
Direct/Reverse Operation
0D28
2D14
PID ON/OFF
0D2C
2D16
Program Pattern
0D32
2D19
Minimum Output ON/OFF
Band
0D40
2D20
Adaptive Control
0D42
2D21
Model Creation PV
Amplitude
0D44
2D22
Model Creation MV
Amplitude
0D46
2D23
Model Creation ON Time
0D48
2D24
Model Creation OFF
Time
0E00
2E00
Transfer Output Type
0E02
2E01
Transfer Output Signal
0E0C
2E06
Control Output 1 Assign-
ment
0E0E
2E07
Control Output 2 Assign-
ment
*1
P.END (program end output) can be set even when the program pattern is set to OFF, but the function will be disabled.
*2
You cannot set these values if you do not use the logic operation function.
E5@D Digital Temperature Controllers Communications Manual (H225)
5 Communications Data for Modbus
Setting (monitor) value
H'00000000 (0): Reverse operation
H'00000001 (1): Direct operation
H'00000000 (0): ON/OFF
H'00000001 (1): 2 PID control
H'00000000 (0): OFF
H'00000001 (1): STOP
H'00000002 (2): CONT
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 (0): Disabled
H'00000001 (1): Fixed
H'00000002 (2): Notification
H'00000003 (3): Automatic update
H'00000000 to H'0000270F (0.00 to 99.99)
H'00000000 to H'000003E8 (0.0 to 100.0)
H'00000000 to H'0000270F (0 to 9999)
H'00000000 to H'0000270F (0 to 9999)
H'00000000 (0): OFF
H'00000001 (1): Set point
H'00000002 (2): Set point during SP ramp
H'00000003 (3): PV
H'00000004 (4): MV (heating)
H'00000005 (5): MV (cooling)
H'00000000 (0): 4 to 20 mA
H'00000001 (1): 1 to 5 V
• Control output 1 is a relay output or voltage output (for driving SSR): Advanced
H'00000000 (0): Not assigned.
H'00000001 (1): Control output (heating)
H'00000002 (2): Control output (cooling)
H'00000003 (3): Alarm 1
H'00000004 (4): Alarm 2
H'00000005 (5): Alarm 3
H'00000006 (6): Alarm 4
H'00000007 (7): Heater alarm
H'00000008 (8): HB alarm
H'00000009 (9): HS alarm
H'0000000A (10): Input error
H'0000000B (11): Not assigned.
H'0000000C (12): Program end output
H'0000000D (13): RUN output
H'0000000E (14): Integrated alarm
*2
H'0000000F (15): Work bit 1
*2
H'00000010 (16): Work bit 2
*2
H'00000011 (17): Work bit 3
*2
H'00000012 (18): Work bit 4
*2
H'00000013 (19): Work bit 5
*2
H'00000014 (20): Work bit 6
*2
H'00000015 (21): Work bit 7
*2
H'00000016 (22): Work bit 8
• When control output 1 is a linear current output:
H'00000000 (0): Not assigned.
H'00000001 (1): Control output (heating)
H'00000002 (2): Control output (cooling)
Control output 2 is a relay output or voltage output (for driving SSR):
H'00000000 to H'0000006 (0 to 22)
Note: Same as for the Control Output 1 Assignment parameter.
Initial setting
Advanced
function
setting
Initial Setting
function
setting
*1
Level
5
5 - 9