6 Programless Communications
(2) We will change the communications settings for CH1.
Change the following settings, and then click the OK Button. Use the defaults settings for
the other parameters.
• Parity Bit: Exist
• Even/odd parity: Even
• Stop bit: 2
• Sum check code: Exist
• Online Change: Enable
• Setting modifications: Enable
• Communication rate setting: 115,200 bps (This setting can be changed after you change
the communications protocol setting.)
• Communication protocol setting: MC protocol (Format 4)
Note: If you change the station number setting, refer to 6-2-8 Communications Node Number
(3) Select Online - Write to PLC. A dialog box to write the set values will be displayed.
6 - 58
E5@D Digital Temperature Controllers Communications Manual (H225)