Digital temperature controllers
Hide thumbs Also See for E5 D Series:

Advertisement

Address
Parameter name
Four-byte
Two-byt
mode
e mode
0426
2413
Power ON Time Monitor
0428
2414
Ambient Temperature
Monitor
0500
2500
Operation/Adjustment
Protect
0502
2501
Initial
Setting/Communications
Protect
0504
2502
Setting Change Protect
0506
2503
PF Key Protect
0508
2504
Move to Protect Level
050A
2505
Password to Move to
Protect Level
050C
2506
Parameter Mask Enable
0600
2600
Manual MV
0602
2601
Set Point
0608
2604
Heater Current 1 Value
Monitor
060A
2605
MV Monitor (Heating)
060C
2606
MV Monitor (Cooling)
0702
2701
Proportional Band
(Cooling)
0704
2702
Integral Time (Cooling)
0706
2703
Derivative Time (Cooling)
0708
2704
Dead Band
070A
2705
Manual Reset Value
070C
2706
Hysteresis (Heating)
070E
2707
Hysteresis (Cooling)
E5@D Digital Temperature Controllers Communications Manual (H225)
5 Communications Data for Modbus
Setting (monitor) value
H'00000000 to H'0000270F (0 to 9999)
When temperature unit is °C: H'FFFFFFE2 to H'0000004B (-30 to 75)
When temperature unit is °F: H'0000000A to H'000000AB (10 to 171)
H'00000000 (0):
No restrictions in operation and adjustment levels
H'00000001 (1):
Move to adjustment level is prohibited.
H'00000002 (2):
Display and change of only "PV" and "PV/SP"
parameters is allowed.
H'00000003 (3):
Display of only "PV" and "PV/SP" parameters is
allowed.
H'00000000 (0):
Move to initial setting/communications setting
level is allowed. (Move to advanced function
setting level is displayed.)
H'00000001 (1):
Move to initial setting/communications setting
level is allowed. (Move to advanced function
setting level is not displayed.)
H'00000002 (2):
Move to initial setting/communications setting
level is prohibited.
H'00000000 (0): OFF (Changing of setup on controller display is
allowed.)
H'00000001 (1): ON (Changing of setup on controller display is
prohibited.)
H'00000000 (0): OFF
H'00000001 (1): ON
H'FFFFF831 to H'0000270F (−1999 to 9999)
H'FFFFF831 to H'0000270F (−1999 to 9999)
(Can only be set. The monitor value is always H'00000000.)
H'00000000 (0): OFF
H'00000001 (1): ON
Standard control:
H'FFFFFFCE to H'0000041A (−5.0 to 105.0)
Heating and cooling control:
H'FFFFFBE6 to H'0000041A (−105.0 to 105.0)
SP lower limit to SP upper limit
H'00000000 to H'00000226 (0.0 to 55.0)
Standard control:
H'FFFFFFCE to H'0000041A
(−5.0 to 105.0)
Heating and cooling control:
H'00000000 to H'0000041A
(0.0 to 105.0)
H'00000000 to H'0000041A (0.0 to 105.0)
H'00000001 to H'0000270F (0.1 to 999.9)
H'00000000 to H'0000270F
(0 to 9999: Integral/derivative time unit is 1 s.)
(0.0 to 999.9: Integral/derivative time unit is 0.1 s.)
H'00000000 to H'0000270F
(0 to 9999: Integral/derivative time unit is 1 s.)
(0.0 to 999.9: Integral/derivative time unit is 0.1 s.)
H'FFFFF831 to H'0000270F
(−199.9 to 999.9 for temperature input)
(−19.99 to 99.99 for analog input)
H'00000000 to H'000003E8 (0.0 to 100.0)
H'00000001 to H'0000270F
(0.1 to 999.9 for temperature input)
(0.01 to 99.99 for analog input)
H'00000001 to H'0000270F
(0.1 to 999.9 for temperature input)
(0.01 to 99.99 for analog input)
Level
Advanced
function
setting
Protect
5
Manual
control
Operation
Adjustment
5 - 3