You can use the settings in the following table for the upload settings and download settings.
0
Nothing assigned.
1
Communications Monitor
2
Status (Upper Word)
3
Status (Lower Word)
4
Status 2 (Upper Word)
5
Status 2 (Lower Word)
6
Decimal Point Monitor
7
Process Value
8
Internal Set Point
9
Multi-SP No. Monitor
10
Spare
11
Heater Current 1 Value Monitor
12
Heater Current 2 Value Monitor
13
Leakage Current 1 Monitor
14
Leakage Current 2 Monitor
15
Soak Time Remain
16
MV Monitor (Heating)
17
MV Monitor (Cooling)
18
Valve Opening Monitor
19
Power ON Time Monitor
20
Ambient Temperature Monitor
21
Control Output 1 ON/OFF Count Monitor
22
Control Output 2 ON/OFF Count Monitor
30
Nothing assigned.
31
Set Point
32
Alarm Value 1
33
Alarm Value Upper Limit 1
34
Alarm Value Lower Limit 1
35
Alarm Value 2
36
Alarm Value Upper Limit 2
37
Alarm Value Lower Limit 2
38
Alarm Value 3
39
Alarm Value Upper Limit 3
40
Alarm Value Lower Limit 3
41
Alarm Value 4
42
Alarm Value Upper Limit 4
43
Alarm Value Lower Limit 4
44
Manual MV
45
Heater Burnout Detection 1
46
Heater Burnout Detection 2
47
HS Alarm 1
48
HS Alarm 2
49
SP 0
50
SP 1
51
SP 2
52
SP 3
53
SP 4
54
SP 5
55
SP 6
56
SP 7
57
Process Value Input Shift
E5@D Digital Temperature Controllers Communications Manual (H225)
Set value
6 Programless Communications
Set value
58
PV Input Slope Coefficient
59
Spare
60
Spare
61
Proportional Band
62
Integral Time
63
Derivative Time
64
Proportional Band (Cooling)
65
Integral Time (Cooling)
66
Derivative Time (Cooling)
67
Dead Band
68
Manual Reset Value
69
Hysteresis (Heating)
70
Hysteresis (Cooling)
71
Soak Time
72
Wait Band
73
MV at Stop
74
MV at PV error
75
SP Ramp Set Value
76
SP Ramp Fall Value
77
MV Upper Limit
78
MV Lower Limit
79
MV Change Rate Limit
80
Extraction of Square Root Low-cut Point
81
Work Bit 1 ON Delay
82
Work Bit 1 OFF Delay
83
Work Bit 2 ON Delay
84
Work Bit 2 OFF Delay
85
Work Bit 3 ON Delay
86
Work Bit 3 OFF Delay
87
Work Bit 4 ON Delay
88
Work Bit 4 OFF Delay
89
Work Bit 5 ON Delay
90
Work Bit 5 OFF Delay
91
Work Bit 6 ON Delay
92
Work Bit 6 OFF Delay
93
Work Bit 7 ON Delay
94
Work Bit 7 OFF Delay
95
Work Bit 8 ON Delay
96
Work Bit 8 OFF Delay
97
Spare
98
Spare
99
SP Response Proportional Band
100
SP Response Integral Time
101
SP Response Derivative Time
102
Disturbance Proportional Band
103
Disturbance Integral Time
104
Disturbance Derivative Time
105
Input Digital Filter
106
Water-cooling Output Adjustment
107
Water-cooling Proportional Band
Increase Threshold
108
Water-cooling Proportional Band Decrease Threshold
6