Digital temperature controllers
Hide thumbs Also See for E5 D Series:

Advertisement

3 Communications Data for CompoWay/F
Variable
Address
type
C3 (83)
0038
C3 (83)
0039
C3 (83)
003A
C3 (83)
003B
C3 (83)
003C
C3 (83)
003D
C3 (83)
003E
C3 (83)
003F
C3 (83)
0040
C3 (83)
0041
C3 (83)
0045
C3 (83)
0046
C3 (83)
0047
C3 (83)
0048
C3 (83)
0049
C3 (83)
004A
C3 (83)
004B
C3 (83)
004C
C3 (83)
004D
*1
The setting (monitor) range depends on the transfer output type setting. (Refer to Section 5 Parameters in
@
the E5
D Digital Temperature Controllers User's Manual (Cat. No. H224).)
*2
After communications parameters have been changed, reset the Digital Controller to enable them.
3 - 12
Parameter name
Alarm 1 ON Delay
H'00000000 to H'000003E7 (0 to 999)
Alarm 2 ON Delay
H'00000000 to H'000003E7 (0 to 999)
Alarm 3 ON Delay
H'00000000 to H'000003E7 (0 to 999)
Alarm 1 OFF Delay H'00000000 to H'000003E7 (0 to 999)
Alarm 2 OFF Delay H'00000000 to H'000003E7 (0 to 999)
Alarm 3 OFF Delay H'00000000 to H'000003E7 (0 to 999)
Transfer Output
H'00000000 (0): OFF
Type
H'00000001 (1): Set point
H'00000002 (2): Set point during SP ramp
H'00000003 (3): PV
H'00000004 (4): MV (heating)
H'00000005 (5): MV (cooling)
Transfer Output
H'FFFFF831 to H'0000270F (−1999 to 9999)
Upper Limit
Transfer Output
H'FFFFF831 to H'0000270F (−1999 to 9999)
Lower Limit
Control Output 1
H'00000000 (0): 4 to 20 mA
Signal
H'00000001 (1): 0 to 20 mA
RT
H'00000000 (0): OFF
H'00000001 (1): ON
HS Alarm Use
H'00000000 (0): OFF
H'00000001 (1): ON
HS Alarm Latch
H'00000000 (0): OFF
H'00000001 (1): ON
HS Alarm
H'00000001 to H'000001F4 (0.1 to 50.0)
Hysteresis
LBA Detection
H'00000000 to H'0000270F (0 to 9999)
Time
LBA Level
H'00000001 to H'0000270F
(0.1 to 999.9 for temperature input)
(0.01 to 99.99 for analog input)
LBA Band
H'00000000 to H'0000270F
(0.0 to 999.9 for temperature input)
(0.00 to 99.99 for analog input)
*2
H'00000000 (0): CompoWay/F
Protocol Setting
H'00000001 (1): Modbus
H'00000002 (2): Disabled
H'00000003 (3): Host Link (FINS)
H'00000004 (4): MC protocol (Format 4)
H'00000005 (5): Dedicated protocol (Format 4)
Send Data Wait
H'00000000 to H'00000063 (0 to 99)
*2
Time
Setting (monitor) value
E5@D Digital Temperature Controllers Communications Manual (H225)
Level
Advanced
function
setting
Initial
setting
*1
*1
Advanced
function
setting
Communi
cations
setting