Network Settings In The Service Center - Siemens SINUMERIK MC Commissioning Manual

Mcu commissioning: nc, plc, drive
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Element of the window
Network
Rotate
Reboot
Shutdown
Note
Data backup and restore with CompactFlash cards
If there is a CompactFlash card in the slot of the PC system, you will not be able to back up or
restore data via the Service Center.
Instead, start the "ghost32.exe" program via the prompt of the Service Center.
10.5.4

Network settings in the Service Center

You can make network settings in the main menu of the Service Center by clicking "Network":
● IP settings at the enterprise network interface X1 (Local Area Connection 2)
● IP settings at the plant network interface X2 (Local Area Connection)
● Configuration of the host
● Configuration of IP routing
Note
Temporarily storing network settings in the Service Center
Any network settings you make in this dialog box are immediately effective, but temporary.
To change network settings permanently, switch to the Service Desktop.
Further information can be found in Chapter Configuration of the Service Center (Page 199).
Overview
IP settings
You can make the following IP settings in the "Network Settings" dialog box:
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
Purpose
Making network settings (Page 247).
Any network settings you make in this dialog box are temporary. To change network settings permanently,
switch to the Service Desktop.
Rotates the screen through 90° in the clockwise direction.
Restart the PC system.
Shut down the PC system.
Installing and setting up PCU Base for IPC
10.5 Backing up and restoring data
247