Siemens SINUMERIK MC Commissioning Manual page 239

Mcu commissioning: nc, plc, drive
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Section
Setting
[processing_
StartState=
loginphase]
continueSetups=
scanSetupDirs=
scanRemovableDrive
SetupDirs=
scanNetworkDrive
SetupDirs=
waitTimeDevicesDete
ction=
waitTimeDriveLetter
sAssignment=
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
10.4 Installing and configuring updates and automation software
Description
Specifies whether the PCU Installer is active before the Desktop run-up.
The setting StartState=activated is required, in particular, if an installation re‐
quires a cold start.
Possible values:
PCU Installer starts setups
activated
PCU Installer is stopped completely
stopped
Some setups can only be completed after the system has been restarted. In this case,
the PCU Installer waits until you restart the PC system.
You can specify here whether setups such as these are to be continued after a restart.
Further information: Note: Troubleshooting for incorrect installation routines
(Page 241)
Possible values: yes; no
Specifies whether setup directories are to be checked and, if required, setup files
executed before the Desktop run-up.
The following directories are checked if this setting has been activated:
Local setup directories from the [local_setupdirs] setting are always checked.
You can define separately whether additional directories on removable data stor‐
age media or in the network are to be checked. (See settings "scanRemovable‐
DriveSetupDirs" and "scanNetworkDriveSetupDirs")
If you deactivate this setting, neither local directories, nor directories on removable
data storage media or in the network are checked, i.e. the setting scanSetupDirs=no
overwrites, for example, scanNetworkDriveSetupDirs=yes.
Possible values: yes; no
Specifies whether directories on removable data storage media are to be checked from
the setting [removable_setupdirs] and, if required, setup files executed before the
Desktop run-up.
The setting "scanSetupDirs" must also be activated so that these directories are
checked.
Possible values: yes; no
Specifies whether network directories are to be checked from the setting [net_setup‐
dirs] and, if required, setup files executed before the Desktop run-up.
The setting "scanSetupDirs" must also be activated so that these directories are
checked.
Possible values: yes; no
Specifies the maximum wait time for device detection (removable data storage media)
in the system run-up. This setting is only relevant if the PCU Installer searches for
setups on removable data storage media prior to the desktop run-up. (See settings
"scanSetupDirs", "scanRemovableDriveSetupDirs" in the section [processing_logi‐
nphase] and section [removable_setupdirs])
Possible values:
Positive integer (milliseconds)
infinite
Specifies how long the PCU Installer will wait during the system run-up until the system
has assigned a drive letter to all of the logical drives. This setting is only relevant if the
PCU Installer searches for setups on removable data storage media prior to the desk‐
top run-up. (See settings "scanSetupDirs", "scanRemovableDriveSetupDirs" in the
section [processing_loginphase] and section [removable_setupdirs])
Possible values:
Positive integer (milliseconds)
infinite
Installing and setting up PCU Base for IPC
239

Advertisement

Table of Contents
loading

Table of Contents