Configuring saving Windows log files

As a result of Windows updates and other operations, larger quantities of data can accumulate
that are no longer required, e.g. temporary update and system files or Windows log files
(CBS.log).
PCU Base for IPC contains 2 batch files, which you can use to configure how files such as these
are saved:
● Deactivate saving
– Saving new log files CBS.log is deactivated, and existing files are deleted:
– The temporary directory is cleared once:
– The data storage medium cleanup is carried out.
● Activate saving
– Reactivates that new log files CBS.log are saved for diagnostics.
You can refer to the information file in the following directory to identify whether the log files are
being saved or not: C:\Windows\Logs\CBS
Precondition
● You require administrator rights to run batch files.
Procedure
1. Switch to directory D:\etc .
2. Double-click on the appropriate batch file.
10.4.4

Configuring a key filter for HMI software

To prevent unwanted interruption of the HMI software while it is running, you can specify that
certain keyboard entries will be filtered out and thus ignored.
You can configure the key filter in the pcuhwsvc.ini configuration file:
● This key filter is not activated as delivered.
● You can activate the key filter and individually select which of the 20 filterable keyboard
entries will be ignored. During this, you can deactivate known shortcut keys, for example, or
even deactivate individual add-on keys, such as the left (SeqActive_16) or right
(SeqActive_17) Windows key.
You cannot configure any additional keyboard entries to be filtered.
● You can also completely deactivate the repeat function of the F1-F12 keys and all hard keys
with the key filter. When the repeat function is deactivated, a key held pressed is considered
as pressed once and not as pressed repeatedly.
Per default, the repeat function is activated during Service or Desktop operation.
228
C:\Windows\Logs\CBS
C:\Windows\Temp
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB