5.4.8

Loading the PLC program to the PLC

Introduction
For loading the configured PLC project, the following preconditions must be fulfilled:
Precondition
● A network connection exists between the PG/PC and the PLC.
● The configuration to be loaded corresponds to the actual station configuration.
● You have loaded the hardware configuration into the module.
● The MCU is active:
– NCK is in cyclic mode.
– PLC in RUN or STOP mode.
Procedure
1. In the project tree, right-click "MCU_1 > PLC_1" and select "Load to device > Software
(changes only)" from the shortcut menu.
The "Load preview" dialog box opens.
2. In the "Download preview" dialog box, check the settings and then click "Load" to confirm
the input.
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
PLC commissioning
5.4 Creating a PLC program
95