Hardware configuration of SIMATIC IPC

10.1.2.1

Network settings

The supported SIMATIC IPCs have two Ethernet interfaces, which are set by the PCU Base for
connection to the SINUMERIK system.
Table 10-1
Hardware
designations
X1
X2
The network designation may deviate depending on the system.
1
Note
The SINUMERIK MCU 1720 CNC and SIMATIC IPC427E and IPC477E industrial PCs are
equipped with 3 Ethernet interfaces. Interface X3 is optional, and is not supported by the
PCU Base for IPC software.
Further information
● Operating instructions of the SIMATIC IPC
● Setting the IP address and domain (Page 184)
● Adapting the firewall settings (Page 202)
● Remote access for diagnostics (Page 272)
● Network settings in the Service Center (Page 247)
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
SIMATIC
Designation in
PCU Base
1
Local Area Connection 2 Preset as a standard DHCP client for connection to a com‐
Local Area Connection
Installing and setting up PCU Base for IPC
Configuration
pany network.
The IP address is dynamically fetched from the DHCP server
at X1.
Preset as SINUMERIK DHCP server for the internal MCU
connection from NC/PLC with IPC in the system network.
At X2, when installing PCU Base, IP address
192.168.214.241 is automatically configured in the system
network.
10.1 Delivery state
177