Hardware Protection: Hardware protection refers to a state in which programming/erasing of
flash memory is forcibly suspended or disabled. At this time, the flash memory control register
(FLMCR) and erase block register (EBR1 and EBR2) settings are cleared.
Details of the hardware protection states are given below.
Item
Description
Programming
When 12 V is not being applied to the
voltage (FV
)
FV
PP
PP
protect
are initialized, and the program/erase-
protected state is entered. To obtain
this protection, the V
not exceed the V
voltage. *
Reset/standby
In a reset, (including a watchdog timer
protect
reset), and in sleep, subsleep, watch,
and standby mode, FLMCR, EBR1,
and EBR2 are initialized, and the
program/erase-protected state is
entered. In a reset via the RES pin, the
reset state is not reliably entered
unless the RES pin is held low for at
least 20 ms (oscillation settling time) *
after powering on. In the case of a
reset during operation, the RES pin
must be held low for a minimum of 10
system clock cycles (10φ).
Notes: 1. Three modes: program-verify, erase-verify, and prewrite-verify.
2. All blocks are erase-disabled, and individual block specification is not possible.
3. For details, see section 6.9, Flash Memory Programming and Erasing Precautions.
4. For details, see AC Characteristics in section 13, Electrical Characteristics.
6.7.9

Interrupt Handling during Flash Memory Programming/Erasing

If an interrupt is generated while the flash memory is being programmed or erased (while the P or
E bit is set in FLMCR), an operating state may be entered in which the vector will not be read
correctly in the exception handling sequence, resulting in program runaway. All interrupt sources
should therefore be masked to prevent interrupt generation while programming or erasing the flash
memory.
pin, FLMCR, EBR1, and EBR2
voltage should
PP
power supply
CC
3
Functions
Program
Erase
Disabled *
Disabled
Disabled *
Disabled
4
Rev. 6.00 Sep 12, 2006 page 149 of 526
Section 6 ROM
Verify *
1
2
Disabled
2
Disabled
REJ09B0326-0600