H8/3937r, h8/3937 series tfp-100g user system interface cable (hs3937ecn61h) for e6000 emulator (21 pages)
Summary of Contents for Renesas H8/36014
Page 1
On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
Page 2
Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
Page 3
H8/36014 Group, H8/36024 Group FP-48B User System Interface Cable for E6000 Emulator User’s Manual HS36014ECH64H Renesas Microcomputer Development Environment System Rev.2.0 2003.12...
Page 4
6. The prior written approval of Renesas Technology Corp. is necessary to reprint or reproduce in whole or in part these materials. 7. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination.
Renesas) pursues a policy of continuing improvement in design, performance, functions, and safety of the user system interface cable. Renesas reserves the right to change, wholly or partially, the specifications, design, user's manual, and other documentation at any time without notice.
User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of Renesas's warranty.
Page 7
This user's manual and user system interface cable are copyrighted and all rights are reserved by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any form, in hard-copy or machine-readable form, by any means available without Renesas's prior written consent.
Page 8
• READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol.
Page 9
Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance.
Page 10
Preface Thank you for purchasing this user system interface cable (HS36014ECH64H) for the Renesas’s original microcomputer H8/36014series. The HS36014ECH64H is a user system interface cable that connects an H8/36014series E6000 emulator (HS3664EPI61H; hereinafter referred to as the emulator) to the IC socket for a FP-48B package for the H8/36014series MCU on the user system and to the H8/36024 series expansion I/O board (HS36024EIO61H).
Section 1 Configuration...1 Section 2 Connection Procedures ...3 Connecting User System Interface Cable to Emulator Station (H8/36014 Series)... 3 Connecting User System Interface Cable to Expansion I/O Board (H8/36024 Series)... 5 Connecting User System Interface Cable to User System... 7 2.3.1...
Section 1 Configuration Use an NQPACK048SD socket (manufactured by Tokyo Eletech Corporation) for the FP-48B package IC socket on the user system. Figure 1 shows the configuration of the HS36014ECH64H user system interface cable for the FP-48B package. Figure 1 HS36014ECH64H User System Interface Cable CAUTION...
Page 13
Table 1 lists the HS36014ECH64H components. Please make sure you have all of these components when unpacking. Table 1 HS36014ECH64H Components No. Component Cable body Cable head IC socket Socket cover Screws (M2 x 10 mm) Screws (M2 x 6 mm) CTS screws (M3 x 6 mm) Guide pins ( 1 mm) Screwdriver...
Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station (H8/36014 Series) Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
Page 15
Figure 2 Connecting User System Interface Cable to Emulator Station...
Connecting User System Interface Cable to Expansion I/O Board (H8/36024 Series) Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
Page 17
Expansion I/O board cable Cable body connector CTS screws (M3 x 6 mm) User system interface cable Figure 3 Connecting User System Interface Cable to Expansion I/O Board...
Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
2.3.3 Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-48B package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4.
Page 20
Fasten the user system interface cable head to the IC socket for a FP-48B package on the user system with the four screws (M2 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-48B package (NQPACK048SD: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad.
Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. ± Figure 7 Dimensions for User System Interface Cable Head...
Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. ± Figure 8 Resulting Dimensions after Connecting User System Interface Cable...
Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Section 4 Verifying Operation 1. When using the H8/36014 series E6000 emulator (HS3664EPI61H), turn on the emulator according to the procedures described in the H8/300H Series E6000 Emulator User's Manual (HS300HEPI61HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins.
Page 28
Figure 10 shows the system clock oscillator on the user system interface cable. Figure 10 System Clock Oscillator...
Place the emulator station, user system interface cable, and user system as shown in the example in figure 11. Connecting User System Interface Cable to Emulator Station (H8/36014 Series) Connecting User System Interface Cable to Expansion I/O Board (H8/36024 Series)
Page 31
Publication Date: Rev.1.00, July 25, 2002 Rev.2.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2002, 2003 Renesas Technology Corp. All rights reserved. Printed in Japan...
Page 32
H8/36014 Group, H8/36024 Group FP-48B User System Interface Cable for E6000 Emulator User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10B0093-0200H...