MANUAL SGM800
2.1.15 Menu -tCL-
tCL
Theoretic calibration
In this menu, the Theoretic calibration settings can be set. Here you can set a
calibration without using a reference weight. For this you only need the specification
sheets of the used loadcells. Options are:
tCL 1
tCL 2
tCL 3
tCL 4
tCL 5
Press key 2 <2 sec to enter the theoretic calibration settings.
The following screen is visible:
In tcL 1 you can set the maximum loadcell load. When more then one loadcell is used all
loadcells should have the same maximum load. Press key 2 <2 sec. to set the maximum
load.
The following screen is visible:
Maximum load loadcells
Sensitivity loadcell 1
Sensitivity loadcell 2
Sensitivity loadcell 3
Sensitivity loadcell 4
81