MANUAL SGM800
In Ind 6 you set the decimal point. The decimal point defines the point position of
the weight value.
To change the decimal point press key 2 < 2 sec.
The following screen is visible:
Press key 1 to define the point position and confirm by pressing key 3 for >2 sec.
Left
Right Confirm
The following screen is visible:
In Ind 7 you set the Display refreshment speed. The Display refreshment speed defines
the times the weigher value is refreshed per second. Options are: 1, 2, 3, 5, 10, 25, 50.
To change the display refreshment speed press key 2 < 2 sec.
The following screen is visible: