MANUAL SGM800
SGM850 (Serial):
Here you can set (for both RS232 and RS422):
Protocol: Set the Protocol that is used on the serial port. Options are: None, Printerm
ASCII, NPV Slave, Modbus RTU, Modbus ASCII.
Address: set the address of the SGM850 on the communication bus.
Stopbits: set the stopbits of the SGM850 on the communication bus.
Paritiy: set the parity of the SGM850 on the communication bus. Options are: None,
Odd, Even, Mark, Space.
Baudrate: set the speed communication of the SGM850. Options are: 1200,
2400, 4800, 9600, 19200, 38400, 57600, 115200.
Indicator: Set the Indicator that is sent out over the communication bus.
SGM860 (Profinet):
There are no settings to configure.
29