2.1.11 Menu -FIL-
- - FIL
Filter settings
In this menu, the filter settings can be set. The display filter will damp the weigher signal
to the display to get a calm display view.
Options are:
FIL 1
FIL 2
FIL 3
FIL 4
Press key 2 <2 sec to enter the filter settings.
In FIL 1 you can set the display filter band. Set the band where the filter is
active. This parameter works together with FIL 2. Choose a value between –99999 kg
and 999999 kg. Press key 2 <2 sec. to change the filter band.
The following screen is visible:
Use key 1 and 2 to change the value. Key 1 is for changing the number (1-9), key
2 is for changing the position of the cursor. Confirm by pressing key 3 for >2 sec.
Up
The following screen is visible:
Display filter band
Display filter factor
Zero suppressing
Shown indicator on display
Down
Left
Right
Confirm