Parameters
List of parameters
r1454
CO: Speed controller system deviation I component / n_ctrl sys_dev Tn
SERVO, VECTOR
Can be changed: -
(n/M)
Data type: Floating Point
P-Group: Closed-loop control
Not for motor type: REL
Min
- [RPM]
Description:
Displays the system deviation of the I component of the speed controller.
When the reference model is inactive (p1433 = 0 Hz), this parameter corresponds to the system deviation of the
complete PI controller (r1454 = r0064).
r1454
CO: Velocity controller system deviation I component / v_ctrl sys_dev Tn
SERVO (Lin)
Can be changed: -
Data type: Floating Point
P-Group: Closed-loop control
Not for motor type: REL
Min
- [m/min]
Description:
Displays the system deviation of the I component of the velocity controller.
When the reference model is inactive (p1433 = 0 Hz), this parameter corresponds to the system deviation of the
complete PI controller (r1454 = r0064).
p1455[0...n]
CI: Speed controller P gain adaptation signal / n_ctrl Adpt_sig Kp
SERVO, VECTOR
Can be changed: T
(n/M)
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the source for the adaptation signal to additionally adapt the P gain of the speed controller.
Dependency:
Refer to: p1456, p1457, p1458, p1459
p1455[0...n]
CI: Velocity controller, P gain adaptation signal / v_ctrl Adpt_sig Kp
SERVO (Lin)
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the source for the adaptation signal to additionally adapt the P gain of the velocity controller.
Dependency:
Refer to: p1456, p1457, p1458, p1459
1-402
Calculated: -
Dynamic index: -
Units group: 3_1
Max
- [RPM]
Calculated: -
Dynamic index: -
Units group: 4_1
Max
- [m/min]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Max
-
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 3
Func. diagram: 5040
Unit selection: p0505
Expert list: 1
Factory setting
- [RPM]
Access level: 3
Func. diagram: 5040
Unit selection: p0505
Expert list: 1
Factory setting
- [m/min]
Access level: 3
Func. diagram: 5050
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 5050
Unit selection: -
Expert list: 1
Factory setting
0