392 Technical data

Additives, tap water

* NOTE Damage caused by mixing addi‐
®
tives with AdBlue
or from diluting
®
AdBlue
®
The BlueTEC
exhaust gas aftertreatment
system could be destroyed by:
®
additives in AdBlue
R
®
diluting AdBlue
R
®
Only use AdBlue
in accordance with
#
ISO 22241.
Do not add additives.
#
®
Do not dilute AdBlue
#
Storage
Tanks made of the following materials are not
®
suitable for storing AdBlue
aluminium
R
copper
R
copper alloys
R
non-alloy steel
R
galvanized steel
R
When stored in such tank, components of these
metals can separate and destroy the BlueTec
exhaust gas aftertreatment.
Only use tanks made of the following materials
®
for storing AdBlue
:
Cr-Ni steel acc. to DIN EN 10 088-1/2/3
R
Mo-Cr-Ni steel acc. to DIN EN 10 088-1/2/3
R
polypropylene
R
polyethylene
R
Disposal
+
ENVIRONMENTAL NOTE Environmental
pollution caused by environmentally irre‐
sponsible disposal
®
Dispose of AdBlue
in an environmen‐
#
tally responsible manner.
®
When disposing of AdBlue
requirements for the country you are currently in.

Purity

To prevent malfunctions at the BlueTec
.
gas aftertreatment, always pay attention to the
purity of AdBlue
If you pump AdBlue
during a repair, do not refill it into the tank. Oth‐
:
erwise the purity of the liquid is no longer guaran‐
teed.

Compressed-air system

®
, observe the legal
* NOTE Damage and malfunctions caused
by impurities in AdBlue
®
Impurities in AdBlue
result in the following:
higher emission values
R
damage to the catalytic converter
R
engine damage
R
malfunctions in the AdBlue
R
aftertreatment system
Avoid impurities in AdBlue
#
®
.
®
out of the tank, for example,

Operating data

Minimum pressures
Pressure
Brake circuit 1
6.8 bar
Brake circuit 2
6.8 bar
Brake circuit 3
5.5 bar
Transmission circuit/
5.5 bar
clutch circuit
Spring-loaded brake
6.8 bar
cylinder release pres‐
sure
Supply pressures
Pressure
Service brake
10.5 - 13.6 bar
Air suspension
10.5 - 15.5 bar
External compressed-
11.0 - 12.5 bar
air source (charging
the compressed-air
system)
Remaining pressure
7.0 - 8.7 bar
circuits
®
®
exhaust gas
®
.
®