Data Related To Safety Standards; Safety Data; Failure Rates - ABB MicroFlex e190 User Manual

Hide thumbs Also See for MicroFlex e190:
Table of Contents

Advertisement

206 Appendix: Safe Torque Off (STO)

Data related to safety standards

Safety data

Frame SIL /
PL
SILCL
UEI
3
e 98.32% 3.04E-09 2.33E-05 13943 ≥90
Proof test interval (PTI) T
Mean repair time MRT = 0 h (circuit boards are not intended to be repaired).
Mean time to restoration MTTR = 48 h (MRT plus time used to locate the failure).

Failure rates

Channel
Total
CHX
CH1
CH2
Tested with:
• Control board build version:
3AXD100000451859 Rev.03.
• Power unit build version:
3AXD100000446920 Rev.03.
• Firmware build version: MicroFlex e190 Build 5850.1.34 and later.
SFF
PFH
PFD
D
[%]
[1/h]
[1/h]
= 2 years.
1
λ
λ
sd
su
[FIT]
[FIT]
209.2
225.0
15.2
6.8
191.0
217.8
194.0
218.3
MTTF
DC
SC Cat. HFT CCF Lifetime
G
d
[%]
[a]
3
λ
dd
[FIT]
0.7
0.0
0.7
0.7
[a]
3
1
80
20
λ
SFF
du
[%]
[FIT]
7.4
98.3%
2.8
88.6%
4.6
98.9%
4.6
98.9%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents