154 Technical data

DC input (supply) connection

Voltage
Ratings
Terminals

Motor connection

Motor types
Frequency
Current
Switching frequency
Maximum motor cable
length
Terminals

Brake resistor connection

Description
Nominal switching threshold
Nominal power
(10% peak power, r = 57 Ω
Peak power
(10% peak power, r = 57 Ω
Maximum brake switching current
Minimum load resistance
Maximum load inductance
270...340 V DC ±10%
Drive type
MFE190-04xx...
-01A6-2
-03A0-2
-06A0-2
-09A0-2
I
is the average DC input current requirement.
dcN
Detachable screw terminal block for 0.20...6 mm
Asynchronous induction motors, asynchronous servo motors,
synchronous permanent magnet motors
0...550 Hz
See section
Ratings.
8 kHz
50 m (164 ft) with screened cable
Detachable screw terminal block for 0.20...6 mm
I
dcN
(A)
1.96
3.67
7.35
11.02
Unit
V DC
on: 388, off: 376
kW
kW
A
pk
µH
C
(µF)
560
560
1120
1120
2
wire.
2
wire.
All models
0.25
2.7
10
39
100