STO cable

Type
Maximum length
Example cable

Ambient conditions

Description
Operating temperature range
Minimum
Maximum
Storage temperature range
Humidity
(maximum, non-condensing)
Maximum installation altitude
(above m.s.l.)
non-STO parts:
STO function:
Shock
Vibration
* Subject to derating; see page 149.
Appendix: Safe Torque Off (STO) 205
2
2×2×0.75 m
low voltage, single shielded, twisted
pair cable
30 m between STO inputs and the operating
contact
Li YCY TP 2×2×0.75 mm
cable by HELUKABEL or CEAM
Unit
1.6 A model
°C
0
+32
+55*
+122*
°C
-40 to +85
°F
-40 to +185
%
95
m
1000. Above 1000 m derate 1.1% / 100 m
ft
3280. Above 3280 ft derate 1.1% / 330 ft
m
2000
ft
6560
10 G
1 G, 2-200 Hz
2
shielded twisted pair
3 A, 6 A, 9 A models
°F
°C
0
+55
All models
°F
+32
+131