ABB MicroFlex e190 User Manual page 62

Hide thumbs Also See for MicroFlex e190:
Table of Contents

Advertisement

62 Electrical installation: input / output
Typical input circuit to provide 0-10 V (approx.) input from a 24 V source:
+24 V DC
Analog input - typical connections from a PLC/controller:
PLC/controller
Analog input - typical connections from an ABB AO561:
AO561
potentiometer
0 V
Shield
Connect overall shield at one
end only
O0U+
13
O01-
17
SG
18
Connect overall shield at one
end only
X3
19
AI0
9
ADC.0
(
8
MicroFlex e190
+15V
X3
AI0+
19
AI0-
9
-15V
MicroFlex e190
+15V
X3
AI0+
19
AI0-
9
-15V
)
Mint
ADC.0
Mint
ADC.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents