Code
Warning
40023
Default MAC detected
(_ecDEFAULT_MAC_DETE
CTED)
40024
Could not open license file or
Error reading license file
(_ecMISSING_LICENCE_FI
LE)
40025
Licence file doesn't match
hardware
ID(_ecFOREIGN_LICENCE
_FILE_PRESENT)
40026
Invalid Licence file
(_ecINVALID_LICENCE_FIL
E_PRESENT)
40027
Warning applying parameter
value
(_ecPARAM_WARNING)
40028
Warning fan fault
(_ecFAN_FAULT_WARNIN
G)
See
AN00267 ABB Motion Drives Error trouble shooting manual
error handing.
Cause
Default MAC has been
detected, valid MAC
address is not set.
Could not open license file
or Error reading license file
Wrong licencing version or
platform,or Flash unique ID
does not match the one in
the license file
Licence data hash does not
match the one in the
Licence File
This warning will be
generated if an attempt is
made to write to a
parameter that is no longer
supported.
The fan is possibly faulty,
unplugged or jammed.
Fault tracing 121
What to do
Set valid MAC address
If this error is received, please contact ABB
technical support.
If this error is received, please contact ABB
technical support.
If this error is received, please contact ABB
technical support.
If necessary recommission the drive to
create a new parameter table
Firstly ensure the latest firmware is in use
(as the fan is controlled by firmware). Check
the bottom of the drive to determine that
the fan inlets are not blocked and the fan is
rotating. If the drive fan does not turn see
the drive installation manual for instructions
on how to replace the fan
for more details on