82 Electrical installation: input / output
Pin
X8B (extra Inc. encoder without Halls)
1
2
3
4
5
6
7
8
9
The inputs may be used as differential inputs (recommended for improved noise
immunity) or single ended inputs. When used as single ended inputs, leave the
CHA-, CHB- and CHZ- pins unconnected. The overall cable shield (screen) must be
connected to the metallic shell of the D-type connector. The encoder supply on pin 12
provides 5.5 V to the encoder (500 mA maximum, less if other encoder inputs are in
use; see page 76). Maximum cable length is 30 m.
Extra incremental encoder cable connections:
Encoder
Feedback
Encoder
Feedback
CHA+
CHB+
CHZ+
(NC)
DGND
CHA-
CHB-
CHZ-
+5.5 V out
Twisted pairs
Connect overall
shield to connector
backshells
Corresponding pin on X8
6
8
15
(NC)
13
5
7
14
12
X8
1
1
9
9
Used by incremental encoder
2
2
without Halls, BiSS-B, SSI,
10
10
EnDat 2.2, or Smart Abs primary
3
3
encoder
11
11
+5.5 V out
12
12
DGND
13
13
Extra incremental encoder:
CHA+
6
CHA-
5
CHB+
8
CHB-
7
7
CHZ+ (INDEX)
15
CHZ- (INDEX)
14