Incremental Encoder Input/Output (X7) - ABB MicroFlex e190 User Manual

Hide thumbs Also See for MicroFlex e190:
Table of Contents

Advertisement

Incremental encoder input/output (X7)

The incremental encoder input/output connection provides A/B channels and a Z
index channel. Twisted pairs must be used for each complementary signal pair e.g.
CHA+ and CHA-. The Mint keyword ENCODEROUTCHANNEL is used to set the mode
of operation for X7. When set to the default value of -1, X7 operates as an input.
Pin 1
1
CHA+
2
CHB+
3
CHZ+
4
(NC)
5
GND
Input mode: ABZ incremental encoder (default)
By default, X7 is configured as an extra ABZ incremental encoder input (encoder 2).
When operating as an encoder input, X7 can be used for a dual-loop feedback
system or connected to a master encoder for position following applications.
Incremental encoder cable connections:
Encoder
Feedback
Input mode: Step (pulse) and direction
Optionally, connector X7 can be configured as a step and direction input. Use one of
the following methods to select step and direction mode.
• In Mint WorkBench, choose the Parameters tool and expand the Encoder family.
Click the EncoderMode entry, then click the value next to EncoderMode (Encoder
Channel 2). Check Bit 2: Step/Direction, then click OK. On the menu, choose
Tools, Store Drive Parameters.
• In Mint WorkBench, choose the Edit & Debug tool. In the Command window enter
the command: ENCODERMODE(2)=4 (or other value where bit 2 is set). On the
menu, choose Tools, Store Drive Parameters.
Electrical installation: input / output 83
6
CHA-
7
CHB-
8
CHZ-
9
+5.5 V out
Twisted pairs
Connect overall
shield to connector
backshells
X7
CHA+
1
CHA-
6
CHB+
2
CHB-
7
CHZ+ (INDEX)
3
CHZ- (INDEX)
8
+5.5 V out
9
DGND
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents