7-4
Adjusting the Hydraulic Pump to Match the
Frequency (Only for Machines Used in 400 V Area)
Machines used in 400 V area are set up for
50 Hz when they are shipped. When the
machine is installed in the area of 60 Hz,
set the following.
CAUTION
- Be sure to turn the adjusting
screw clockwise.
Remove the lower front cover.
Loosen the lock nut in the rotor
pump section, and turn the ad-
justing screw clockwise by 180
degrees.
We recommend to make a mark before
rotating the screw.
Tighten the lock nut again, and
install the lower front cover.
Lower Front Cover
Lock Nut
Adjusting Screw
Turn this screw by 180
degrees clockwise.