1152700 Issue 1 February 2001 Section 2 Operations and Maintenance
Table 101-2. Alphabetical NMIC Generated Alarm Reports, continued
ALARM
SEVERITY
MESSAGE
NMIC Full
Minor
Database
Restoration
Failed
NMIC Full
Informatio
Database
nal Alert
Restoration
Needed
NMIC lost
Informatio
connection
nal Alert
with NMIC
application
NMIC lost
Informatio
connection
nal Alert
with NMIC
resources
agent
NMIC lost
Informatio
connection
nal Alert
with peer
NMIC
NMIC
Informatio
Protection
nal Alert
Change
Notification
NMIC
Informatio
Protection
nal Alert
Switch
Notification
Physical
Major
Fiber Failure
Second
Informatio
NMIC
nal Alert
Plugged into
Invalid Slot
Page 2-442
© 2000, ADC Telecommunications, Inc.
IMPACT
DESCRIPTION
Not
Informs user that the NMIC
Service
database restoration attempt
Affecting.
has failed.
Not
Informs user that the NMIC
Service
cards (working and protect)
Affecting
are out of sync.
Not
Informs user that the NMIC
Service
had a failure resulting in a
Affecting
loss of connection with its
application.
Not
Informs user that the NMIC
Service
had a failure resulting in a
Affecting
loss of connection with its
resource agent.
Not
Working NMIC cannot
Service
communicate with the
Affecting
protection NMIC.
Not
An informational alert
Service
informing the user that the
Affecting
protection mode has been
changed. This may be due to
a Lockout or an Automatic
Protection Switch (APS)
being initiated.
Not
An informational alert
Service
indicating the NMIC has
Affecting
started the process of
switching to the protect card.
Not
Network has experienced a
service
failure on one of the fiber
affecting
interconnections between the
nodes, indicated on the GUI
screen as an orange
connection.
Not
Informs the user that the
Service
protection NMIC is not
Affecting
seated into the proper slot in
the backplane.
TAP-100
Page 23 of 23
SUGGESTED COURSE OF ACTION
Check statuses of NMICs and
reattempt database restoration.
Perform a database restoration
to synchronize the information
on the NMIC cards. Refer to
DLP-719.
This event will result in a
protection switch if the second
NMIC is in sync and protection
switching is enabled.
This event will result in a
protection switch if the second
NMIC is in sync and protection
switching is enabled.
Protection switching will not be
enabled at this point. Try
reseating standby NMIC. May
need to perform a database
restoration upon reestablishing
communication paths.
No action necessary. Verify the
protection operation change is
required and revert back if it is
not.
No action necessary. Verify
card switches properly upon
completion.
Check NE alarm reports at each
end of the fiber. Any LOS or
Section AIS on the hop may
cause this alarm.
Remove the protection NMIC
and reinstall into slots 4 and 5.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Release 3.1 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Cellworx stn

Table of Contents

Save PDF