Page 1
™ ADC FlexWave Prism Host, Remote and EMS 5.1 System Reference ADCP-77-073 Issue 2 11/2009 Quad Band Remote Unit Host Unit Antenna Antenna Antenna 77073-001 Antenna D-620098-0-20 Rev B CORNING EX1005, page 001 IPR2021-00762...
Page 2
CD. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
ADC FlexWave Prism systems. Familiarity with SNMP and common network technologies is required. Each FlexWave Prism document describes a different aspect of the FlexWave Prism system. The following manuals correspond to this FlexWave Prism release: Title ADCP Number ADC®...
1.9 AWS and PCS Band Options ................24 This section provides a basic description and application and configuration information about the FlexWave Prism system. Throughout this publication, all items referenced as “accessory items” are not furnished with the basic product and must be purchased separately.
• • Support for millimeter wave backhaul • • With its unique use of wideband digital RF transport, FlexWave Prism delivers reliable and consistent performance in all environments. Signals are not affected by reflection, dispersion, or frequency attenuation over fiber.
Coarse Wavelength Division Multiplexer (CWDM) system, and expansion panels are available as accessories. Control and monitoring functions are provided by the FlexWave Element Management System (EMS). Some examples of FlexWave Prism Systems are shown in Figure 1-1, Figure 1-2, Figure 1-3.
ULTI YSTEMS ADC’s FlexWave Prism provides a Multi-Host feature that allows a Prism Remote to be shared by multiple Host Units. To accomplish this: • • One Host is designated as the IP Manager for a set of Remotes; this Host can serve as IP manager for multiple Remotes.
5 MHz of digitized RF spectrum. Utilizing the full 12 timeslots yields between 60 and 80 MHz of total digitized RF on each SeRF SFP laser connection. FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 19 ADCP-77-073 •...
FlexWave Prism System ANDWIDTHS In the FlexWave Prism system, there are different Bandwidths from which to select, ranging from 5 to 75 MHz. The different bandwidths allow you to configure the system to use any contiguous or non-contiguous blocks within the 35 MHz of a single Host 6-timeslot DART or 60-75 MHz using a 12-timeslot DART.
RF signals over extended distances, without the RF degradation that normally results when analog systems are impacted by optical effects. The basic function of the FlexWave Prism platform is to transport via fiber optic cable RF signals from a Base Transceiver Station (BTS) to an antenna interface allowing communication to a mobile device.
Page 43
FlexWave Prism Family Overview The basic function of FlexWave Prism simulcast (point-to-multipoint) is to transport, via fiber optic cable, RF signals from a Base Transceiver Station (BTS) to multiple antenna interfaces allowing communication to a mobile device (see Figure 2-2). Up to 8 simulcast Remotes are supported.
Host Network Connection The SeRF front panel has a Network port that creates a network connection between the Host and the network to monitor and configure the FlexWave Prism system through the FlexWave EMS. The network interface connection between the Host and the network is supported by a Gigabit Ethernet (10/100/1000) RJ-45 jack with integrated green ACTIVITY and LINK LEDs.
75347-0006 Figure 2-9. Linear Power Amplifier The FlexWave Prism Remote 40W RF Module is designed for AWS and PCS frequencies. The Prism Remote 40W RF Module comprises one DART, two Linear Power Amplifiers (LPAs), and one or two Remote DART Interface (RDI) boards (two for a diversity module and one for a non-diversity module).
Page 66
CWDM Mux/DeMux unit and Figure 2-19 shows the CWDM Fiber Cable Assembly. For further information on the Prism CWDM system, see the ADC FlexWave™ Prism Coarse Wavelength Division Multiplexer User Manual (ADCP-75-353). LEFT SIDE PORTS (DEMUX) RIGHT SIDE PORTS (MUX)
Page 67
77073-057 Figure 2-19. CWDM Fiber Cable Assembly The Prism CWDM system works with ADC’s 7- and 3.5-inch industry-standard WideVAM chassis to ensure consistent, superior cable management within the frame. The 3.5-inch standard VAM chassis fits into any 19-inch rack mounting environment.
Page 68
Prism System Components The 7-inch standard VAM chassis fits into any open chassis location within an existing ADC 7-inch panel system or in an LGX® compatible frame. It accommodates a maximum of six components, in any combination of the following: •...
A Millimeter Wave (MMW) system with a data rate of not less than 3 Gbps (that meets the FlexWave Prism data rate performance and BER requirements) may be used in applications where it is desirable or necessary to bridge an open span and where it is impractical to lay a fiber optic cable.
Page 89
35 5 Repeat this procedure for the remaining SeRF SFPs in the Host. 36 6 Store any excess patch cord slack at the fiber distribution panel or storage panel. FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 75 ADCP-77-073 •...
Page 91
Host from the right side of the rack may exceed the bend radius limitations for the optical fiber. 47 7 (Optional) If adding CWDM accessories, see the ADC FlexWave™ Prism Coarse Wavelength Division Multiplexer User Manual (ADCP-75-353) for installation information.
The SeRF front panel provides a Craft port that provides an Ethernet interface that allows you to connect a computer to access the EMS. 51 1 Connect one end of an Ethernet cable (CAT5 or better, not provided by ADC) to the Host Craft port as shown below.
Installing the Remote Unit EMOTE OUNTING LANS The FlexWave Prism Remote Unit has a low profile design that requires minimal real estate for installation. The basic dimensions and weights of the Remote are listed in Table 4-2. Table 4-2. Remote Dimensions...
Installing the Remote Unit 4.4.10 Mount the Remote and Power Up 52 2 Refer to the detailed instructions for mounting the FlexWave Prism Remote in the Remote Unit Mounting Kit Installation Instructions (ADCP-77-077) to mount the Remote in the location selected in Section 4.2, Remote Mounting Plans, on page...
FlexWave Element Management System EMS O VERVIEW The ADC FlexWave EMS is an embedded software application that is accessed through an internet connection using a Web browser and provides a Graphical User Interface (GUI) for control and monitoring of a Prism system.
Product Identity RODUCT DENTITY The FlexWave Prism system comprises a mix of URH Hosts and Prism Remotes. The system components are therefore identified as follows in the EMS: • • Login screens— ™ ADC FlexWave Prism&URH • • Summary views—...
Page 159
4 4 When the window opens: ADC FlexWave Prism&URH Embedded Web Server Welcome In the box, type the user name provided by ADC or by the Network Username Administrator. The default user name is admin. b b In the box, type the password provided by ADC or by the Network Password Administrator.
Network port. The maximum cable length is 300 feet (91.4 m). Use the following procedure to install the Network cable and then log in to the EMS. FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 189 ADCP-77-073 •...
Page 207
The user name (viewer) and password (viewer) used to access the EMS through the Remote Craft port cannot be changed. 10 0 Click . The Welcome to ADC FlexWave Prism Embedded Web Server page opens. FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 193 ADCP-77-073 •...
Page 219
If the user was logged on to the system during this procedure, the user needs to log off and then log back on again to put the new access level into effect. FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 205 ADCP-77-073 •...
Page 251
Restarting an LPA may need to be replaced. Contact ADC Technical Assistance for further help (see “Contacting ADC” on page 335). • —Red indicates an internal VSWR fault state of the LPA. Check the LPA VSWR Fault Remote’s antenna connection. If the connection is good and a subsequent LPA reset does not clear the alarm, inspect the blue cable going from the corresponding Remote Antenna port to the Duplexer—verify that the connection...
12.2.2 MIB Used by FlexWave System The FlexWave system uses a single MIB called the ADC-FLEXWAVE-URH.mib. The MIB resides on the SeRF card in the Host where the EMS software also runs. The SNMP proxy agent software required for the interface with SNMP managers also resides and runs on the Host SeRF card.
You can't use both a static and dynamic trap agent configuration. You can only use one or the other. If you configure static, the dynamic entries will be deleted. FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 283 ADCP-77-073 •...
EPAIR XCHANGE OLICY All repairs of ADC Products must be done by ADC or an authorized representative. Any attempt to repair or modify ADC Products without written authorization from ADC voids the warranty. If a malfunction cannot be resolved by the normal troubleshooting procedures, call the Technical Assistance Center at 1-800-366-3891, extension 73476 (in U.S.A.
Upon receipt of the defective Product, ADC will credit Buyer with 20 percent of full price charged for any Product to be Out-of-Warranty. Products must be returned within thirty (30) days to be eligible for any advance replacement credit.
Page 345
Delay RF propagation delay, which can be set for a linked Host DART and Remote DART using an EMS window or command. FlexWave Prism Element Management System, the software application documented in this document. ENET Port Ethernet port capable of CAT5 transmission.
Page 346
The EMS uses HTTP to allow access to a Host or Remote through its IP address. Host Unit FlexWave Prism network element that receives an RF signal from the BTS and converts it to an optical signal to its paired Remotes. Linear Power Amplifier(LPA) An electronic module in the Remote.
Page 349
ADCP Number: Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.