AT commands
Parameter
0x00
0x01
0x02
Parameter
0
1
2
Default
0x00

SB (Stop Bits)

Sets or displays the number of stop bits for the UART.
Parameter range
0 - 1
Value
0
1
Default
0
RO (Packetization Timeout)
Set or read the number of character times of inter-character silence required before transmission
begins when operating in Transparent mode.
Set or read the number of character times of inter-character silence required before transmission
begins when operating in Transparent mode.
Set RO to 0 to transmit characters as they arrive instead of buffering them into one RF packet.
Parameter range
0 - 0xFF (x character times)
Default
3

FT (Flow Control Threshold)

Set or display the flow control threshold.
XLR PRO Radio Frequency (RF) Module User Guide
Description
No parity
Even parity
Odd parity
Description
No parity
Even parity
Odd parity
Description
One (1) stop bit.
Two (2) stop bits.
Serial interfacing commands